Description:
Replacement window customers will want to ascertain a replacement window's U-Factor which will indicate the level of thermal insulation that the window offers

U-Factor A window's U-Factor indicates the rate of heat loss of a window unit. Window manufacturers measure a window's resistance by its insulating properties. This measurement is indicated as a U-Factor. The lower a U-Factor, the higher the level of a window's thermal insulation.

Contents

Measuring the U-Factor

The U-Factor refers to a window's overall heat transfer coefficient. Using standardized conditions the U-Factor measures the rate of heat transfer that passes through a window. Smaller U-Factors have the highest potential reduce heat transfer.

Measuring Heat Gain and Heat Loss

The U-Factor is just one of the components that measures the rate at which a window loses and gains heat. A window's total thermal insulation is measured by the U-Factor along with Air Leakage (AL) and the Solar Heat Gain Coefficient (SHGC).

National Fenestration Ratings Council Ratings

The U-Factor sometimes refers to just the glass or glazing alone but the National Fenestration Ratings Council, whose ratings are accepted as industry standards, assesses the entire window performance, including frame and spacer material. These ratings include the U-Factor, the Solar Heat Gain Coefficient and Air Leakage.

Energy Star Ratings

Energy-Star-Windows windows whose label is recognized for purposes of government tax credits and rebates, only bases its qualification on the U-factor and the Solar Heat Gain Coefficient ratings. The Energy Star label is granted based on ratings for the U-Factor and the Solar Heat Gain Coefficient as measured by the national Fenestration Ratings Council.

U-Factor

The U-factor measures the rate at which a window conducts non-solar heat flow. The lower the U-factor, the more energy-efficient the window.

Solar Heat Gain Coefficient

The Solar Heat Gain Coefficient is the fraction of solar radiation which is admitted through a window. It is either directly transmitted and/or absorbed. The SHGF is subsequently released as heat within a building.

Air Leakage

Air Leakage refers to the rate of air movement surrounding a window. Air Leakage is expressed in units of cubic feet per minute per square foot of frame area. A window unit with a high Air Leakage is not as tight as one with a low air leakage rating.

Center-of-Glass U-Factor

The National Fenestration Ratings Council offers a nationally recognized rating method. The ratings provided by the NFRCassesses the total window performance including the frame, spacers and glazing. The Center-of-Glass U-Factor is sometimes indicated. Center-of-Glass only describes the performance of the window's glazing and does not include the effects of the framing material. Homeowners should be aware that the most energy efficient windows will have a higher whole window U-factor than the center-of-glass U-factor.

U-Factor Averages

High thermal performance double-glazed windows will display a U-factor of 0.30 or lower. Some high performance triple-glazed windows can achieve a U-factor of as low as 0.15.

U-Factors in Varying Climates

Homes located in colder climates should include windows with low U-factors.

 